The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The placement of Thyristor controlled series capacitor (TCSC) reduces transmission losses, increases the available capacity, and improves the voltage profile. This paper presents the implementation of the thyristor switched series capacitor in the transmission network of the power system. The TCSC has been installed in series with the two parts of the transmission line. The performance of the system...
Power systems are complex systems consisting of large number of generating units and interconnected network of transmission lines. The voltage stability is an issue of prime importance in this complex power system network since the demand for electric power is increasing drastically. The control of reactive power in the transmission lines will enhance the voltage stability of the power system network...
The power system faults do occur in power system network and are more frequent in transmission and distribution systems. The behaviour of power system faults changes in the presence of FACTS devices. Accurate detection of these faults is essentially required for providing effective power system protection and relaying system. The relays must operate as fast and accurate as possible to switch off the...
The placement of shunt capacitor banks at optimal locations in the distribution network and their sizing can effectively reduce the losses in the utility network. It also helps in the maximum active power flow through the existing distribution lines which. This also increases the power transfer capacity of feeders and improves the voltage profile of the feeders which leads to reduced investment of...
Transmission line protective relaying is an important aspect of a reliable power system operation. The issue has become critical due to wide spread grid integration of distributed energy sources. The power system faults do occur in power system network and are more frequent in transmission and distribution systems. The behaviour of faults changes in the presence of renewable energy (RE) sources. This...
The transient components are introduced in the extra high voltage (EHV) transmission lines during the faulty conditions. The transients may damage the power system equipments as well as may also lead to the mal-operation of the equipments utilized for a specific application in the power network. These transient components are intensified in the presence of distributed generation (DG) sources such...
The relaying is an important aspect for the protection of transmission lines, generators, bus-bars, and transformers for reliable power system operation. The issue of protection has become critical due to increased grid integration of distributed energy sources. The relaying systems continuously monitor the voltage and currents in the power system and generate commands to isolate the faulty part of...
The transmission line relaying is an extremely important device used to provide the protection of transmission and distribution of the power system. The relays must operate as fast as and as accurate as possible to switch off the faulted line in order to protect the system against the harmful faulty effects. The wide spread use of power electronics based devices in the power system has made the protection...
Recently the open-access and competitive market power policy has been adopted by the utilities. Now, the electricity consumers are in a position to demand and expect a higher quality of service. The utilities and power providers have to provide a high quality of service to remain competitive as well as to retain or attract the customers. To achieve this goal an efficient power quality (PQ) monitoring...
The transient components are introduced in the extra high voltage (EHV) transmission lines during the faulty conditions. The transients may damage the power system equipments as well as may also lead to the mal-operation of equipments utilized for a specific application in the power network. Analysis of faults in the presence of series compensation in the EHV transmission line may help to design suitable...
The insulation system of the power transformer is a critical aspect of its health condition and the failure of the insulation system can make the transformers out of service. High voltage (HV) bushings and windings are the most important components of the transformer insulation system. This paper presents a study of industrial manufacturing and testing procedures of transformer board insulation. A...
The installed power capacity of grid-connected wind energy conversion systems (WECSs) has increased exponentially around the world. The size of each unit is also increasing as they are becoming more affordable. The grid is a highly non-linear system due to wide spread use of power electronically switched loads and devices. Hence, the grid disturbances affect the output of the WECSs. This paper presents...
The Paper presents study of 11 kV rural feeder emanating from Jaipur Discom, Jamwa Ramgarh 33 kV GSS. The haphazard growth in agricultural load in these areas resulted in high transmission losses. The Rampura feeder having 230 Buses has been electrical modeled using Mi-Power Software. The load flow study has been performed to assess the feeder loss, loading of 11 kV lines, Distribution transformers...
The fault-generated transient components, which contain abundant fault information and are immune to the system's inconstancy, have been widely used in the fault detection and classification by means of travelling-wave or high-frequency transients. The analysis of faults with different loads helps in the detection of transients which ultimately helps in the localization, detection and classification...
Since 1945, electric power systems have been extremely important due to huge increase in the electric energy demand. As a result, power transmission lines have been rapidly developed in number and length. Any disturbance or the tripping of transmission line may lead to failure of supply in wide area. This requires the effective protection of these lines. The analysis of faults with different loads...
The installed power capacity of grid-connected photovoltaic (PV) systems has increased exponentially around the world. The size of each unit is also increasing as they are becoming more affordable. The grid is a highly non-linear system. Hence, the grid disturbances affect the output of the solar PV systems. This paper presents a study of the effects of grid disturbances such as switching of loads,...
Recently the electrical Power quality (PQ) has become a main concern for both utilities and customers because the load side on the costumer side gets affected and may get damage. This paper presents a discrete wavelet transform (DWT) based technique for the detection of power system operational events and power quality disturbances associated with these events. The power quality disturbances associated...
This paper addresses the failure of capacitor cells of high voltage (HV) shunt capacitor banks in Rajasthan Rajya Vidhyut Prasaran Nigam Ltd. (RRVPNL) power grid, a transmission network of Rajasthan state of India, due to pole discrepancy among the three poles of circuit breaker (CB). The high voltage peaks detected at the time of capacitor switching, when there is time difference in the closing of...
Optimal reactive power compensation has become an important issue to Indian power system due to initiatives taken towards national grid formation in the country. Presently new grid and southern grid are running in asynchronous mode. Central Transmission Utility (CTU) has forced the regional or state grids to maintain their reactive power compensation as per the requirement of grid as specified in...