The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a structured design method for half-bridge converters with higher-order lossless output filters, focusing on the popular LCL filters. The method builds on the theory of terminated ladder networks and on a control algorithm actively emulating the ladder network's termination. Given a desired transfer function, a normalized ladder network is accordingly synthesized and scaled to...
The use of a digital architecture in PWM controllers for point-of-load (POL) applications, together with system identification techniques, allows the development of fully automated routines for in-situ system performance optimization where controller parameters are specifically tailored to the application. In this context, this paper proposes a method for performing parametric system identification...
Digital Active EMI Filtering (DAEF) technique is a new direction of conductive EMI suppression technologies for switched-mode power converters. However, the conventional DAEF topology only suppresses EMI to ground on the AC (or DC) ports. It doesn't definitely aim to Common Mode (CM) or Differential Mode (DM) EMI. In this paper, a novel DAEF topology is proposed. It can flexibly suppress CM and DM...
Excellent dynamic behavior and controllability even under fault conditions are main requirements of future electric drive systems. The Modular High Frequency Converter (MHF) fulfills these requirements and enables additional advantages especially low weight, low volume and redundant operation after faults. This paper presents control strategies and stability considerations for the new topology of...
This paper presents a digital hybrid ripple-based constant on-time control scheme for voltage regulator modules (VRMs). Due to the sampling effects of the digital implementation, the stability issue becomes worse than the analog ripple-based control schemes, especially when low-ESR decoupling capacitors are used as the output filter. In order to stabilize the system and to fulfill the output impedance...
This paper deals with the high pressure lamps feed by direct conversion AC to AC with ZETA converter implemented by bidirectional switches for the lamp operation on the mains frequency. The aim is to prevent the occurrence of destructive acoustic resonance. Also has high efficiency, high power factor and low cost. The approach focused on passive elements design in the circuit, the transfer function...
This paper proposes a digital control system for a half-bridge boost rectifier, which composes the input stage of a single-phase transformerless double-conversion UPS. The proposed control system has an inner current loop and two outer voltage loops to maintain near unity input power factor and to regulate the dc bus voltages. The control loops operate with distinct sampling frequencies, so that current...
This paper develops a new set of small signal models for buck and boost paralleled and interleaved converters. These models provide a more accurate representation of the small signal behavior of this class of converters by including independent duty cycle control of each paralleled interleaved converter in the model and taking into account the dumping effect from interleaving the converter stages...
This paper characterizes two digital V2 control schemes using for the buck converters with small-ESR capacitors based on the presented small-signal models. Due to the sampling effects of the analog-to-digital converters (ADCs), the digital V2 control system performances are not as good as the analog ones, even using the inductor current sensing feedback. The major issue is that in order to stabilize...
This paper presents an analytical design method of indirect full digital controller with a simple structure for three-phase inverter system. Most of conventional researches on the analytical design of controller have been studied about the structure of continuous-time controller, and so the final implementation of full digital controller for industrial application was complicate and anyway based on...
A novel digital adaptive voltage positioning (digital AVP) technique with dual-voltage-loop was proposed in. Good transient performance had been achieved without using complicated control. In this paper, a small signal model is proposed for this mixed-signal digital controller. It is revealed by this small signal model that the inner current loop is in analog and the voltage loop is in digital, thus...
This paper proposes a CRA based robust digital controller for three-phase PWM VSI inverter. To regulate the inverter output voltage with constant voltage and constant frequency, the usual inverter controller consists of double looped PI controllers. Those are an outer voltage controller and an inner current controller, then the order of system characteristic polynomial is high and so the gain tuning...