The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We present a method for detecting and studying neoplasia-specific functional and structural features through the combination of in vivo dynamic imaging, in silico modeling and global sensitivity analysis. We particularly present the case of cervical epithelium interacting with acetic acid solution, which is employed as an optical biomarker. The in vivo measured dynamic scattering characteristics are...
Patients with diabetes have difficulty controlling their blood sugar and suffer from acute effects of hypoglycemia and long-term effects of hyperglycemia, which include disease of the eyes, kidneys and nerves/feet. In this paper, we describe a new system that is used to automatically control blood sugar in people with diabetes through the fully automated measurement of blood glucose levels and the...
Acute myocardial infarction (AMI) diagnosis in type II diabetes (DM2) patients is difficult and ECG findings are often non-diagnostic or inconclusive. We developed computer algorithms to process standard 12-lead ECG input data for quantitative 3-dimensional (3D) analysis (my3KGTM), and hypothesized that use of the my3KGTM's array of over 100 3D-based AMI diagnostic markers may improve diagnostic accuracy...
A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary...
Signal normalization is an essential part of patient independent algorithms, for example to correct for variations in signal amplitude from different parts of the body, prior to applying a fixed threshold for event detection. Multiple methods for providing the required normalization are available. This paper presents a systematic investigation into the effects of five different methods using epileptic...
Using a phase plane analysis (PPA) of the spatial spread of trajectories of the fetal heart rate and its time-derivative we characterize the fetal heart rate patterns (fHRP) as defined by Nijhuis. For this purpose, we collect 22 fetal magnetocardiogram using a 151 SQUID system from 22 low-risk fetuses in gestational ages ranging from 30 to 37 weeks. Each study lasted for 30 minutes. After the attenuation...
Seizure prediction performance is hampered by high numbers of false predictions. Here we present an approach to reduce the number of false predictions based on circadian concepts. Based on eight representative patients we demonstrate that this approach increases the performance considerably. The fraction of patients for whom we found a significant seizure prediction performance was increased from...
The need of a reliable seizure prediction is motivated by the 50 million people in the world suffering from epilepsy, of whom 30% have no control on seizures with current pharmacological treatments. Seizure prediction research holds great promise for such patients, since an effective algorithm will enable the development of a closed-loop system that intervenes before the clinical onset of a seizure...
The reduction of the number of EEG features to give as inputs to epilepsy seizure predictors is a needed step towards the development of a transportable device for real-time warning. This paper presents a comparative study of three feature selection methods, based on Support Vector Machines. Minimum-Redundancy Maximum-Relevance, Recursive Feature Elimination, Genetic Algorithms, show that, for three...
Individualizing a neurorehabilitation training protocol requires understanding the performance of subjects with various capabilities under different task settings. We use multivariate regression to evaluate the performance of subjects with stroke-induced hemiparesis in trajectory tracking tasks using a force-reflecting joystick. A nonlinear effect was consistently shown in both dimensions of force...
In this study vibrotactile stimulation of the upper leg and its usability for feedback was tested. Three experiments were performed on ten healthy subjects using pager motors. The first experiment was to test the perception of the vibration at different frequencies and at different locations of the upper leg. The second experiment tested the ability of subjects to estimate location and number of stimuli...
Since the 1970s, various automatic sleep spindles procedures have been implemented and presented in the literature. Unfortunately, their results are not easily comparable because the databases, the assessment methods and the terminologies employed are often radically different. In this study, we propose a systematic assessment method for any automatic sleep spindles detection algorithm. We apply this...
In this contribution the evaluation of a system called “Eventlogger” is presented, which is installed in a day hospital for old age psychiatry. The Eventlogger is a radio based module with an adjustable communication range, able to recognize interaction of the user with objects or with other people. It is intended to function as a monitoring tool for the users' activities. Due to the demographic change...
This paper investigates the enhancement of the sensitivity and adsorption efficiency of a localized surface plasmon resonance (LSPR) biosensor that includes a layer of graphene sheet on top of the gold layer. For this purpose, biomolecular interactions of biotin-streptavidin with the graphene layer on the gold thin film are monitored. The performance of the LSPR graphene biosensor is theoretically...
Stimuli responsive hydrogels show a strong ability to change in volume with changes in selected environmental properties. This tendency of these hydrogels to change in volume is captured as pressure-change in confined cavities of pressure sensors. An array of pressure sensors on a single chip may carry hydrogels sensitive to multiple, selected metabolic markers and continuously monitor multiple vital...
The design, fabrication, and measurement results for a diaphragm-based single crystal silicon sensor element of size 820 μm × 820 μm × 500 μm are presented. The sensor element is designed for in vivo applications with respect to size and measurement range. Moreover, it is optimized for longtime operation in the human body through a built-in protection preventing biofouling on the piezoresistors. The...
This paper presents the preliminary results of a study to determine dorsolateral prefrontal cortex sensitivity to rTMS stimulation presented at clinically accepted amplitudes, frequencies and locations. A specially developed EEG system with 10–20 electrode locations was used to record the short latency magnetically evoked potentials. Sixteen normal subjects were stimulated using 10 Hz for the left...
The characterization of visual field loss provides a valuable diagnostic metric for studying the effects of damage to the retina, optic nerve or visual cortex. We describe a tool, the Quadrant Vision Perimeter (QVp), to rapidly and accurately measure visual fields. In addition to measuring the location of visual deficits, the tool can assess modality-specific field loss (e.g., impaired detection of...
To make it viable for remote monitoring to scale to large patient populations, the accuracy of detectors used to identify patient states of interests must improve. Patient-specific detectors hold the promise of higher accuracy than generic detectors, but the need to train these detectors individually for each patient using expert labeled data limits their scalability. We explore a solution to this...
A three-stage study to develop and test an unobtrusive room sensor unit and subject data management system to discover correlation between sensor-based time-series measurements of sleep quality and clinical assessments of combat veterans suffering from Post-traumatic Stress Disorder (PTSD) and mild Traumatic Brain Injury (TBI), is described. Experiments and results for testing sensitivity and robustness...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.