The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The paper presents a brief overview of the standard IEC60255–121 and focusses on the challenges and advantages of using transient simulation for assessing protective relays. The importance of the use of statistical methods to investigate the behaviour of algorithms is discussed. Finally a new solution for performing these kinds of tests is introduced.
Since IEC 61850 became the widely used standard for substation communication with a lot of implementations. Testing is an important issue. The standard in its current version covers some possibilities and approaches for testing in general and for measures of performance. Nevertheless some issues came out which needed to be clarified with the new edition of the standard. Edition 2 will be available...
The paper describes a Transient Bias technique designed to overcome the effects of Current Transformer (CT) saturation, which might severely affect the behaviour of a protection system. This Transient Biasing, as the name implies, is only active during transient conditions in the power system, and it decays quickly once the transients disappear. A complementary algorithm for fast detection of external...
Decentralized Energy Resources (DER) and especially wind farms became a challenge for protection, automation and control in the grids. Transmission system operators as well as distribution system operators require tests of Loss of Mains and other decoupling protection functions. In some countries certification of these functions is required. The units are equipped with a huge amount of internal protection...
With their increasing number, it is getting important that decentralized and renewable energy sources are supporting the stabilization of the system voltage after short voltage dropouts. Often, in the past, these generators were disconnected during network faults. This is not adequate anymore, as it would lead to a loss of a considerable amount of feed-in power. However, if the generators stay connected,...
IEC 61850 is the new standard for communications in substations that defines a new generation of protection applications based on high speed peer-to-peer communications between different substation devices. Accelerated protection schemes use permissive or blocking signals exchanged between relays at the two or more ends of the protected transmission line in order to provide fast fault clearing for...
This paper addresses three aspects of testing relay protection systems using a real time simulator: (1) simplify the setup by using low level analog signals to the relay; (2) use a ‘threading’ process when a hybrid setup (commercial relays and simulated relay models) is chosen; (3) test substation protection system together with control and communication systems.
Protection of power systems requires a high degree of reliability. Whenever a protection is called upon to operate, it must do so. Failure to do so may result in costly damage to plant, loss of supply to many consumers, and potentially, danger to life. Protection relays are designed in such a way as to ensure reliability of operation. Very often, the main threat to reliable operation is the circuit...
Currently, there are many challenges in the development of numerical, multifunctional Intelligent Electronic Devices (IEDs) paraphrased as relays in this paper. These are to continuously improve the design quality, to reduce the development period for shorter time to market, and to optimise the development cost and the product cost. One effective solution for these challenges is to develop automated...
The advent of IEC61850 Standard has ushered a new age for substation automation. This standard has gained a very strong footing in Europe and its application is spreading across the world. In USA the progress towards IEC61850 implementation is relatively slower. IEC61850 holds great promises for substation automation and protection. There are many advantages that this standard brings to the area of...
IEC 61850 is a standard that is now gaining pace within the Electrical Supply Industry and one that is under scrutiny by Network Rail. One of the key advantages offered by IEC 61850 is interoperability based on the fact a standard communications interface is implemented between substation devices. This allows the manufacturer to diversify specific functionality whilst allowing communication with other...