The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We have developed a simple, rapid, inexpensive method for the determination of benzo[a]pyrene (BP, a known carcinogen) in smoking-flavour agents (water-soluble liquid smoke; WSLS). After purification of the WSLS by a single passage through a Sep Pak C18 Plus cartridge, BP in the hexane eluate was determined by second derivative constant-wavelength synchronous spectrofluorimetry. Method precision...
The development of a fiber optic sensor for the analysis of polycyclic aromatic compounds based on laser-induced room-termperature phosphorimetry is reported for the first time. A pulsed nitrogen laser was used to excite phosphorescence emission from compounds imbibed on filter-paper substrates. Thallium(I) acetate (0.1 M) was used to enhance phosphorescence emission from chrysene, 1,2-benzofluorene,...
The presence of a micellar medium of cetylpyridinium bromide (CPB) causes, in relation to the aqueous medium, important bathochromic shifts in the excitation spectra of a considerable number of polycyclic aromatic hydrocarbons (PAHs). Furthermore, the CPB acts as a quencher, provoking inhibitions of the fluorescence intensity emitted by PAHs. The micellar inhibition factors show that, generally,...
GC/MS and GC/MS/MS in a quadrupole ion trap were used to analyze for anthraquinone, alkyl anthraquinones, benz[a]anthracene-7,12-dione and 9-fluoranone in a sediment obtained from an aluminum smelter settling pond contaminated with polycyclic aromatic hydrocarbons. By standard GC/MS analysis many of these target compounds were either undetectable or their confirmation uncertain because of matrix...
A method for the quantitation of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air by high-performance liquid chromatography (HPLC) with a spectrofluorometric detection and programmed excitation and emission wavelength pairs is proposed. The mobile phase is a linear gradient of methanol-water. The relative standard deviations (n = 5) are in the range 0.38-1.7% at concentration levels...
Fluorescence behavior of 41 polycyclic aromatic hydrocarbons (PAHs) dissolved in aqueous micellar cetyltrimethylammonium chloride (CTAC) solvent media and in five different cetyltrimethylammonium chloride + cetylpyridinium chloride (CPC) surfactant mixtures is reported. Experimental fluorescence measurements reveal that CPC is a selective fluorescence quenching agent for alternant PAHs. The cetylpyridinium...
Micellar electrokinetic capillary chromatography (MEKC) with aqueous organic solvent has been developed to separate polycyclic aromatic hydrocarbons (PAHs). Methanol, ethanol or propanol as an organic modifier was added to sodium dodecyl sulfate (SDS) micellar solution in order to increase the solubility of very hydrophobic solutes in mobile phase. Both methanol and ethanol can be used as co-solvents...
Applicability of the cetylpyridinium (CPy + ) cation as a selective fluorescence quenching agent for discriminating between alternant versus nonalternant polycyclic aromatic hydrocarbons (PAHs) is examined for 25 representative solutes dissolved in two aqueous micellar cetylpyridinium chloride (CPC)+zwitterionic surfactant solvent media. Experimental results show that the CPy + cation...
A new sample preparation procedure for the analysis of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) in water containing suspended particulate matter (SPM) has been developed. A specially designed filtration vessel coupled directly to an SPE cartridge was used for this purpose. SPM separation and analyte isolation/concentration were carried out in a single step. Both...
This paper presents a development of a solid support RT phosphorescence procedure for the determination of polycyclic aromatic hydrocarbons, based on the use of a Xenon flash lamp as the excitation source, a fiber optic sensor as a guide of light, an imaging spectrograph and a cooled two dimensional charge coupled device as the detector. Non fluorescent Whatman N o 1 filter paper was used...
This article presents considerable improvements in SPE-RTP methodology for the analysis of polycyclic aromatic hydrocarbons in water samples. Bulky glassware and vacuum pump were removed from the previous extraction procedure [E.D. Hagestuen, A.D. Campiglia, Talanta 49 (1998) 547] by processing 10 ml of sample with syringes and stainless steel filter holders. The oven-drying step was substituted by...
Solid-phase microextraction presents numerous advantages over traditional extraction techniques. However, the determination of partition coefficients is not as simple as it may appear. For very nonpolar compounds, such as polycyclic aromatic compounds, adsorption to the glass wall of the extraction vial and the Teflon coating of the stir bar may be quite significant. These interactions must be taken...
Pyridinium chloride (PC) is examined as a selective, fluorescence quenching agent for alternant as opposed to nonalternant polycyclic aromatic hydrocarbons (PAHs) in two polar solvents - water and acetonitrile. Nine alternant and 13 nonalternant PAHs were dissolved in water and acetonitrile and a total of 0.2 M of pyridinium chloride was added. The resulting change in fluorescence intensity was observed...
In this present study the extraction of polycyclic aromatic hydrocarbons (PAHs) from marine sediments with a micellar medium of Polyoxyethylene 10 lauryl ether by an ultrasound-assisted method has been studied. Factorial design experiments were used in order to optimize the extraction parameters: extraction time, surfactant concentration and surfactant volume:amount of sediment relationship. The results...
The analytical potential of solid-phase extraction and room temperature fluorimetry for screening polycylic aromatic hydrocarbons in water samples is evaluated. Solid-phase extraction was performed via a syringe procedure previously reported (Talanta 52 (2000) 727). The simplicity of fluorescence measurements on the solid substrate is equivalent to solution measurements. Since oxygen quenching of...
A new procedure is presented for the analysis of polycyclic aromatic hydrocarbons by solid-liquid extraction (SLE) and laser-excited time-resolved Shpol'skii spectrometry (LETRSS). Microliters of Shpol'skii solvent are spiked on the surface of the extraction membrane and LETRSS is directly performed on the organic layer above the surface of the solid substrate. Fluorescence measurements are easily...
A back-flushing procedure using porous graphitic carbon (PGC) HPLC columns has been used successfully for the cleanup of soil samples for the determination of benzo[a]pyrene in ppb levels by an ODS-fluorescence HPLC column. The procedure was tested on nine random soil samples taken from an industrial area of the Kingdom of Bahrain. The mean percent recovery from the PGC column was 96% and the average...
This paper presents the characterization of polycyclic aromatic hydrocarbons (PAHs) in solid-surface fluorescence as the first step for obtaining new optical sensors for PAHs screening. The fluorescence properties of the EPA-PAHs (naphthalene, acenaphthene, acenaphthylene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[k]fluoranthene, benzo[b]fluoranthene,...
Optimized separation of a mixture of 16 priority pollutant polycyclic aromatic hydrocarbons (PAHs) by high performance liquid chromatography (HPLC) using the sequential simplex optimization method was accomplished by varying the starting and ending compositions of acetonitrile and water, linear gradient time, mobile phase flow rate, column temperature and holding time of the final mobile phase composition...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.