The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Speciation of elements in natural matrices, especially of trace metals, is one of the predominant development trends of modern inorganic analysis. The main part of the conventional speciation procedures is a suitable combination of separation and chemical conversion steps, for which the most appropriate methodology seems to be the use of flow-injection. A shorter time of performance of these operations...
Management of domestic wastes often relies on incineration, a process that eliminates large amount of wastes but also produces toxic residues that concentrate heavy metals. Those hazardous secondary wastes require specific treatment. Vitrification is seen as a powerful way to stabilise them. However, concern exists about the long term behaviour of these glass wastes and the potential release of toxic...
Sulphoxine cellulose microcolumn was used in an FI-GFAAS system for the preconcentration of trace metals, Cd, Co, Ni, Pb and V from water and from highly mineralised water and also in the presence of complexing agent, e.g. citrate. The recovery was quantitative at pH 5 for all of the elements from NIST 1643c trace elements in water SRM and from highly mineralised water samples. No significant difference...
A general rapid on-line preconcentration method for the determination of trace metals coupled to flame atomic absorption spectrophotometry (FAAS) or ion chromatography (IC) with spectrophotometric detection is described. The method is based on the on-line precipitation of metal hydroxides with sodium hydroxide and their dissolution in a small volume of nitric acid solution. All the chemical and physical...
In this paper an earlier work on the use of poly(acrylamidoxime) cloth for use as a passive monitor for trace metals in water by characterizing the sorption of several metals onto the cloth using a continuous flow chamber is extended. The monitors consists of amidoxime chelating groups covalently bound to the surface of a textile encased in a common 35 mm slide holder. Placement of this device in...
The coupling of adsorptive accumulation with catalytic reactions results in remarkably low (sub-picomolar) detection limits. This review assesses various strategies for attaining such dual-amplification effects, that lead to the most sensitive voltammetric technique, adsorptive-catalytic stripping voltammetry (AdCtSV).
This study considers the selectivity of the extractants used in a sequential extraction scheme for metals mobility assessment by analyzing individual mineral phases previously coprecipitated or sorbed with trace metals. The scheme evaluated was a modification of the Tessier et al. [A. Tessier, P.G.C. Campbell, M. Bisson, Anal. Chem. 51 (1979) 844] sequential procedure proposed by the authors. The...
Comprehensive studies have been carried out on the extraction behavior of uranium and plutonium matrices using cyanex-923 extractant. The near total extraction of U/Pu and quantitative separation of 22 metallic elements at trace levels has been established using inductively coupled plasma-atomic emission spectrometry (ICP-AES). The studies carried out on back extraction of U/Pu from organic phase...
Preconcentration of Cd(II), Cu(II), Mn(II), Ni(II), Pb(II) and Zn(II) in saline matrices on Amberlite XAD-4 resins coated with ammonium pyrrolidine dithiocarbamate (APDC) and piperidine dithiocarbamate (pipDTC) and subsequent determination by inductively coupled plasma atomic emission spectrometry were studied. Parameters such as effect of pH, effect of HNO 3 concentration on elution of metals...
A new design of a continuous flow system applied to the simultaneous determination of the concentration of zinc(II), cadmium(II), lead(II), copper(II), nickel(II), cobalt(II) and chromium(VI) in river water is described. A flow cell made in the laboratory, which has been patented, based on a 'wall-jet' configuration with a three-electrode system is described. Optimum conditions for the determination...
A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 Ω. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO 2 nucleation and growth. As a result,...
A very sensitive flow injection method with spectrophotometric detection has been developed for the on-line determination of copper in natural waters. The method exhibits a limit of detection three times lower than the most sensitive direct spectrophotometric method previously described and then allows the direct and simple in situ determination of copper in most natural waters.The method was based...
The microwave-assisted acid-digestion for the determination of metals in coal by ICP-AES was investigated, especially focusing on the necessity of adding HF. By testing five certified reference materials, BCR-180, BCR-040, NIST-1632b, NIST-1632c, and SARM-20, it was found that the two-stage digestion without HF (HNO 3 +H 2 O 2 was used) was very effective for the pretreatment...
The speciation measurements of trace metals by the diffusive gradients in thin-films technique (DGT) using a poly(4-styrenesulfonate) (PSS) aqueous solution as a binding phase and a cellulose dialysis membrane (CDM) as a diffusive layer, CDM-PSS DGT, were investigated and showed good agreement with computer modelling calculations. The diffusion coefficients of ethylenediaminetetraacetic acid (EDTA)...
The most essential limitation of batch-injection analysis (BIA) methodology compared to other flow methods (CFA, FIA, SIA) is the lack of possibility of on-line sample processing in the measuring system. Some procedures of on-line sample pretreatment in BIA are possible by changing the plastic tip of the automatic micropipette used for sample injection into a flow-through reactor, e.g. by packing...
The present work describes the preparation, optimization and characterization of mixed polyelectrolyte coatings of poly-l-lysine (PLL) and poly(sodium 4-styrenesulfonate) (PSS) for the modification of thin mercury film electrodes (MFEs). The novel-modified electrodes were applied in the direct analysis of trace metals in estuarine waters by square-wave anodic stripping voltammetry (SWASV). The effects...
In this work, we describe an automated stripping analyzer operating on a hybrid flow-injection/sequential-injection (FIA/SIA) mode and utilizing a bismuth-film electrode (BiFE) as a flow-through sensor for on-line stripping voltammetry of trace metals. The instrument combines the advantages of FIA and SIA and is characterised by simplicity, low-cost, rapidity, versatility and low consumption of solutions...
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200–400mesh), with...
A bielectrode array comprising a jalpaite membrane (i.e., Ag 1.5 Cu 0.5 S) copper(II) ion-selective electrode (ISE) and chalcogenide glass membrane (i.e., Fe 2.5 (Se 60 Ge 28 Sb 12 ) 97.5 ) iron(III) ISE has been assembled by individually wiring each solid-state sensor into a single electrode body. Furthermore, a dual metal ion buffer calibration...
A new co-precipitation method was developed to separate and pre-concentrate Fe 3+ , Cu 2+ , Cr 3+ , Zn 2+ , and Pb 2+ ions using an organic co-precipitant, 3-benzyl-4-p-nitrobenzylidenamino-4,5-dihydro-1,2,4-triazole-5-on (BPNBAT) without adding any carrier element, following flame atomic absorption spectrometric (FAAS) determinations. Effect of some analytical...