The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this work, the electro-oxidation of butyl paraben (BuP) in aqueous solutions under different experimental conditions was studied by cyclic voltammetry. For this purpose, platinum and glassy carbon electrodes were employed in different electrolytes such as KCl, H2SO4 and K4P2O7. The best electrochemical response was observed for glassy carbon electrode in the presence of K4P2O7 based on the oxidation...