The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Objective
To compare intraocular pressure (IOP) measurements in dogs taken with the Reichert® Tono‐Vera® Vet rebound tonometer with and without the automatic positioning system.
Animals Studied
Measurements were taken on 49 eyes from 26 Beagle‐derived dogs with variable genetics—four non‐glaucomatous and 22 ADAMTS10‐mutant dogs affected with different stages of open‐angle glaucoma. Seventeen of...
Objective
The objectives of the study were to compare intraocular pressure (IOP) readings across a wide range and obtained via three rebound tonometers in ADAMTS10‐mutant Beagle‐derived dogs with different stages of open‐angle glaucoma (OAG) and normal control dogs and to investigate the effect of central corneal thickness (CCT).
Animals Studied
Measurements were performed on 99 eyes from 50 Beagle‐derived...