The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this work we reported ET (electrical testing) failure case studies related to the process drift of barrier metal deposition (BM) during W via/CA process loops. We presented detailed TEM failure analysis in order to understand the failure mechanism and root cause behind the high via/CA resistance. We demonstrated the importance of TEM characterization and identification of key physical failure signatures...
In this work we reported a case study onET(electrical testing) failure with via high resistance issue. In order to understand the failure mechanism and rootcause behind the high via resistance, detailed TEM(transmission electron microscope) analysis wasperformed by using various TEM FA (failure analysis)techniques, including EDX, EELS analysis. It was foundout that high via resistance arose from the...