The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The basic formulas for analytical determination of the earthing system resistance are given by the European standard EN 50522:2010 [1] in its annex J. As these formulas are rather vague about how to determine the earthing system resistance for more complicated shapes of earthing systems consisting of more basic earthing electrodes (e.g. strip, rod, ring), this formulas are cited in the Czech Republic's...
The paper deals with the issue of response of electronic-based revenue meters during transmission of active energy (power) at harmonic frequencies of higher order. Basic principle of active power measurement which is formed by harmonic components is summarized and expected behaviour of the meters compared with the requirements of currently valid standards for electricity meters is discussed. Consequently,...
The main reasons for installation of power quality meters in distribution transformer substations are power quality monitoring and global evolution of electrical network towards the ‘smart grid’. In case that all measurements from the meters are properly synchronised and centralised, new possibilities of control or evaluation of the network are enabled. This contribution proposes the possibility for...
This paper deals with the description and of the mathematical model of compensated MV distribution network. The model was created in PS Cad in order to solve the ground faults localization using the method of the additional grounding of the healthy phase. This method was experimentally tested for different types of ground faults. The comparison of the measured values and the simulation results is...
The paper deals with an optimization procedure in terms of a network voltage parameters improvement. A software based approach is used to select optimal type of voltage regulator, its power and ideal location for application in a Low-Voltage (LV) test network, where it is required to enhance Voltage Quality (VQ). The test network presents a case where application of on-load tap changer transformer...
The paper is focused on the operational experience with an automatic system for additional earthing of the faulty or healthy phase during an earth fault. The system is primarily used for limiting of a fault current in the point of the fault by earthing of the faulty phase during an earth fault. The equipment for additional earthing of faulty phase can also be used for short-time connection of healthy...
The paper is focused on the operational experience with an automatic system for suppression of a fault current during a ground fault by the additional earthing of the faulted phase in a supply substation. Such system was experimentally installed in the Brno-Medlánky 110/22 kV substation. To verify the benefits of the system as well as to assess its possible failings, twenty-four experimental measurements...
A connection between a phase conductor and the ground in a compensated MV networks is called an earth fault. Since the fault current in this case does not depend on the point of the fault, but only on the total capacity (size) of a network, earth fault location remains a problem for MV network operators. The MV compensated Networks in Czech Republic are operated as nonsymmetrical, that means as networks...
A connection between a phase conductor and the ground in MV networks is called earth fault. The fault current in this case does not depend on the point of the fault, but only on the total capacity (size) of a network. Distribution system operator (DSO) sometimes needs to operate the large network which means operating of the network with big capacitive current (in Czech Republic more than 800A). This...
The paper deals with the description and analysis of the method of the additional earthing of the affected phase used for the elimination of the fault current during an earth fault in a compensated network. The efficiency of this method is strongly influenced by the fault location and resistance and, in some cases, its application can lead to deteriorating the situation at the point of the fault and...
The methods of assessing the place of the ground fault in compensated MV networks are known. At present realizations, the evaluation of ground faults is usually based on using more methods specialized for the detection of individual types of ground faults. The methods used in the paper follow from the analysis of electromagnetic fields of phase conductors and lines. Ground fault indicators have been...
The paper deals with earth fault phenomena in MV compensated networks. There were damaged concrete towers in E.ON Czech Republic distribution network and the aim of experiment was to measure electrical values during the fault. The experiment was prepared and six types of fault for tuned and untuned Petersen coil and for two distances between busbar and point of fault were subsequently connected. The...