The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The High Voltage Converter Modulator (HVCM) systems at the Spallation Neutron Source (SNS) are the primary power sources for the klystrons that supply RF power to the H-beam. The availability of the HVCMs exceeds 99% due to numerous improvements that have been implemented since SNS operations began in 2006. However, the HVCMs continue to operate in open-loop mode that results in significant voltage...
The High Voltage Convertor Modulators are used to power the RF klystrons used throughout the linear accelerator at the Spallation Neutron Source. The output voltage of the modulator has significant voltage droop and ripple which, combined with low level RF system limitations, affect performance and stability of the accelerator cavities. In conjunction with the progress in the development of the new...