The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The patterns of signal that detected by using electric and acoustic emission (AE) methods can be used for the identification of partial discharge (PD) events in power cable. Because the transmission distance of sounds in the insulation layer of power cables is limited, when discharging occurs at continuous or joint positions, a high-frequency current transformer (HFCT) and/or AE sensor can be used...
This paper aims to discuss the measurement and recognition of partial discharge (PD) signals in gas insulation load breaker switch (GILBS) by using high frequency current transformer (HFCT) and acoustic emission (AE) sensors. Three kinds of fault were made purposely within the GILBS that sealed up with SF 6 gas. Then we increase the voltage onto the GILBS until it produce PDs and measure the signals...
The cause of power electric cable fault is often source from the cable splice and cable terminator used in the electric cable connection and the partial discharge released from the improper construction process. It makes the insulation stuff aging and damaged. When the insulation capability becomes worse, it could cause unexpected damage on the high-voltage cables, many industry and research institutes...
In this paper, we analyze and compare the partial discharge (PD) signals from acoustic emission (AE) and high-frequency current transformer (HFCT) measurements with Hilbert-Huang transform (HHT). Commonly, the Fourier transform (FT) method is used to illustrate information in frequency domain. The HHT, a time-frequency method, provides another viewpoint to interpret the PD signals. This method allows...
To detect partial discharge (PD) signal from internal defects or particles in gas insulation system (GIS), both couple capacitor (CC) and acoustic emission (AE) methods are applied in the examinations. According to the measured data, we need to distinguish whether it is PD or particle impact signal. From the CC measurement we can determine whether discharge occurs in one of the GIS chambers or not...
This study adopts the acoustic emission (AE) method to measure partial discharges (PD) in a cast-resin dry-type transformer and proposes a waveguide atop the high-voltage winding of the transformer to improve the propagation of the PD acoustic signals occurring in winding to acoustic emission sensors used. A waveguide is proposed to improve the signalspsila quick attenuation and it also is a safe...
A new, simple partial discharge (PD) detector for low-voltage rotating electrical machines using acoustical emission (AE) technique is developed in this study. Common electric components were used in the detector, which reduces the cost of inspection, comparing with the traditional PD detection methods that use expensive equipment costing from tens of thousands to several millions dollars. Experimental...