The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Corrosion rates from electro-chemical polarization resistance technique (LPR) and weight loss method (WL) of HK-40m alloy exposed to 80 mol% V 2 O 5 -20Na 2 SO 4 at 600 and 700 o C were obtained at a maximum time of 10 days. Results were supported by X-ray diffraction and electron microscopy analysis. A comparison of corrosion rates from both techniques indicated...