The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper, the wet-gas flow modeling for the straight section of a throat-extended Venturi meter was studied. Based on the separated-flow theory, a flow model was presented. The relationship between the fluctuating properties of the differential pressure (DP) over the straight section and the quality of the wet-gas flow was also studied, and a flow model of the fluctuation of the DP for wet-gas...
In this paper, wet gas flow modeling for the straight section of a throat-extended Venturi meter was studied. A static model based on the separated flow theory was presented. Experiments were carried out within static pressure range of 0.26~0.86 MPa, gas volumetric flowrate range of 80~120 m3/h, water volumetric flowrate range of 0.3~4.5 m3/h and quality range of 0.07~0.36. It was obtained that the...