The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This work simulates the main furnace and the convective section of the lignite-fired Ag. Dimitrios V boiler located in Kozani, Northern Greece, under three different thermal loads (100%, 60% and 35% of the nominal one) using the Ansys Fluent 15.0® software program. The lowest thermal load investigated, i.e. 35% of the nominal one, is lower than the current technical minimum of the unit (~55%). In...
The purpose of the current paper is to investigate the Cynara cardunculus (cardoon)/lignite co-firing concept at a 10% biomass thermal share for a 330MW e pulverized fuel plant in Northern Greece. Two main cases are considered: (A) co-milling of pelletized biomass with lignite and (B) milling of balled and/or shredded material in dedicated biomass mills. A CFD model for plant simulation is...