The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This work relies on constructal design to perform the geometric optimization of morphing T-shaped fins that remove a constant heat generation rate from a rectangular basement. The fins are bathed by a steady stream with constant ambient temperature and convective heat transfer. The body that serves as a basement for the T-shaped construct generates heat uniformly and it is perfectly insulated on the...