The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper, an investigation of inverter fault-tolerant field-oriented control for permanent magnet synchronous motor (PMSM) with loss of one transistor or loss of one phase is presented. The basic idea of this design consists in incorporating a fourth legs inverter, with the same topology of the three legs. In this case of fault-tolerant inverter, a redundant leg is added that replaces the faulted...