The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
An algorithm for the construction of the magnetic system of a flowmeter of multiphase fluid media that assures its minimal weight and minimal overall dimensions is presented. The system guarantees high values of the magnetic induction in the working range of the flowmeter (0.5–1.0 T and greater) with high degree of homogeneity (less than (20–30)·10–6) in required volumes.
An algorithm is presented for design of a gradient system for a multiphase flowmeter based on the phenomenon of nuclear magnetic resonance. The designed system forms a gradient field with a specified degree of nonlinearity (±1%) that ensures the required accuracy in measuring the parameters of a multiphase flow.