The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The control of a PWM inverter is affected by variable inductance present in the power line of the grid. This paper presents a new implementation of grid-tied inverter with weighted-average-current feedback control (WAC) and an embedded online technique to determine the grid line impedance. By adding an inter-harmonic voltage periodically in the modulation of the PWM and measuring the current response,...
For a grid-connected converter with an LCL filter, the harmonic compensators of a proportional-resonant (PR) controller are usually limited to several low-order current harmonics due to system instability when the compensated frequency is out of the bandwidth of the system control loop. In this paper, a new current feedback method for PR current control is proposed. The weighted average value of the...
A low cost utility interactive inverter is valuable to the residential PV or fuel cell distributed generations. This paper presents a low cost solution to the single-phase grid-connected inverters, including the inverter topology, filter structure, and the current control methods. The reason for choosing the proposed converter topology is given. A novel current control method using the combinatorial...
This paper proposes a new control strategy for the transition between grid-tied mode and off-grid mode of the utility interconnected fuel cell inverters with an LCL filter. During the transition from grid-tied mode to stand-alone mode, the inverter control is switched to voltage-controlled mode from the beginning of the transition, using inverter instantaneous output voltage regulation to reduce the...
This paper proposes a new control strategy for the transition between grid-tied mode and off-grid mode of the utility interconnected fuel cell inverters with an LCL filter. During the transition from grid-tied mode to stand-alone mode, the inverter control is switched to voltage-controlled mode from the beginning of the transition, using inverter instantaneous output voltage regulation to reduce the...