The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In recent years, permanent magnet synchronous motors (PMSM) are becoming popular in industrial applications. It is difficult to have perfectly balanced 3 phase ac supply voltages in power system. In fact, line supply voltages typically differ by a few volts or more, and hence unbalanced supply voltages can exist anywhere in a three-phase power distribution system. This paper presents a study of PMSM...
It is documented that almost 98% of all voltage generated by electric utilities has up to 3% unbalance. Single phasing fault deserves special attention since phase loss is considered the worst case of unbalanced supply voltage. This paper focuses on unbalanced supply condition diagnosis and discrimination between an unbalance in the supply and phase loss fault. The discrimination will be based on...
Recently, Permanent Magnet Synchronous Motors (PMSM) is one of the most attractive electric machine in industrial applications, therefor must be protected against electrical and mechanical failures for continue their operation safely. However, different kinds of faults are unavoidable in motors during their operational service. Unbalancing in the supply voltage is common in grid supply. However, the...
Permanent magnet synchronous motor (PMSM) is currently the most attractive application electric machine for several industrial applications. It has obtained widespread application in motor drives in recent time. However, different types of faults are unavoidable in such motors. This paper focuses on stator winding faults diagnosis. This paper proposes the ratio of third harmonic to fundamental FFT...
A method for fault detection and diagnosis of stator inter-turn short circuits and unbalanced supply voltages for three phase induction machines is presented. The method is based on the analysis of the ratio of third harmonic to fundamental FFT magnitude component of the three-phase stator line current and supply voltage to detect different insulation failure percentages at different load conditions...