The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Anterior cruciate ligament (ACL) injury and knee osteoarthritis are well-known injuries of the knee joint, and pivot shift is a symptom of the ACL injury. Today, to diagnose the pivot shift phenomenon, the manual testing is examined for the early diagnosis, however, it should be affected by inter- and intra observer variability. This article proposes a novel system for detecting and quantifying the...
The estimation system of the knee joint angle that decreases the variability caused by the subjective diagnosis of the knee joint disorders has been attracting a considerable attention. This paper proposes an unconstraint knee joint angle measurement system using inertial and magnetic composite MEMS sensor. The proposed system estimated the posture difference between the thigh and shank region from...
For estimating 3-D pose position of artificial knee implants in vivo, there are some studies based on 2-D/3-D image registration of 2-D fluoroscopy images and 3-D geometrical model. Knee implant mainly consists of femoral component and tibial component. Most conventional studies estimate 3-D pose position of femoral component and tibial component individually. Rather, they don't evaluate relative...
Analyzing knee kinematics of implanted knee after Total Knee Arthroplasty (TKA) is affective approach in the research area of orthopaedics. There are some studies based on 2-D/3-D image registration of 2-D fluoroscopy images and 3-D geometric model. However, these conventional studies are designed for still statics image analysis, and there are a few studies for dynamic image of continuously knee...
The pivot shift test has been performed to assess the instability of the knee caused by anterior cruciate ligament (ACL) injuries. However, the test depends on the clinician's subjective feeling. In this study, inertial and magnetic sensors have been introduced into quantitative evaluation of the pivot shift test. The analysis method extracts the knee movement of the pivot shift by using wavelet transformation...
Total knee arthroplasty (TKA) is an orthopedic surgery which replaces the damaged knee joint with the artificial one. To diagnose the function of the implanted knee joint, it is effective to estimate 3-D knee kinematics in vivo. There are some conventional methods for estimating kinematics of the implanted knee using 2-D/3-D image registration for X-ray fluoroscopic images and 3-D geometrical models...
Wearable joint kinematics monitoring is effective for analyzing daily human behavior, for evaluating the knee functionality in the daily life, etc. This study proposes a new wearable joint kinematics monitoring system using a composite sensor which is composed of inertial and magnetic sensors. For each segment of the joint, the composite sensor is attached. By indentifying the two sets of acceleration...
Knee kinematics in the every daily life or during the sports activities attracts the considerable attentions. Advances in micro electro mechanical system technologies produce many types of mobile sensors. This article introduces a system-of-systems (SoS) which estimates the knee kinematics by integrating MARG sensor and pressure sensor. Each sensor is with miniature size, low power consumption and...
The pivot shift test has been performed to assess the instability of the knee caused by anterior cruciate ligament (ACL) injuries. However, the test depends on the clinicianpsilas subjective feeling. In this study, inertial and magnetic sensors have been introduced into quantitative evaluation of the pivot shift test. The analysis method extracts the knee movement of the pivot shift by using wavelet...