The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The stability of the injection of short electron beams and the dynamic processes that occur during their transport were experimentally studied. Beams of energy 200-300 keV, current 1-1500 A, and duration 0.05-3 ns with a current rise time of 30-300 ps were formed in a cold-cathode electrode gaps. For measuring beam currents special collector probes were used which ensured a picosecond resolution.
Results of experiments with Microsecond Plasma Opening Switch, operating on the level of 1 TW pertinent to studies of electron and ion flows during the high voltage phase are given. It was shown that in the plasma focus type of POS geometry the ion current reaches 30% of the total stored current amplitude. The average energy of ion flow was considerably lower then respective voltage at the POS. Bad...
The investigation of the nanosecond Plasma Opening Switch (POS) operation with two type of load - short circuited and planar electron diode - was made. With the stored current of 600 kA 450 kA was switched in load inductivity of 15 nH with rise time 5 ns; POS voltage reached 1.3 MV and its impedance − 15 Ohm. With the electron diode load the unefficient turn-on of the diode cathode surface took place:...
One of the most perspective trends of high-current electronics development is the creation of electron beam accelerators with high pulse recurrence frequency [l]. The prospect of this trend is due not only to the possibility of these accelerators to be widely used in physical researches but to their possibility to be used in solution of various problems of applied character. This paper deals with...