The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper reports research into the use of a crossed-electrode two-dimensional thick film lead zirconate titanate ultrasonic transducer array for particle manipulation under the control of electronics based on field programmable gate arrays. The array consists of 30 × 30 transducer elements defined by electrode crosspoints and works at approximately 7.25 MHz. Laser vibrometry of the array surface...
The higher performance of relaxor-based piezocrystals compared with piezoceramics is now well established, notably including improved gain-bandwidth product, and these materials have been adopted widely for biomedical ultrasound imaging. However, their use in other applications, for example as a source of focused ultrasound for targeted drug delivery, is hindered in several ways. One of the issues,...
This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered on an alumina substrate without any subsequent patterning processes. The thickness...
State-of-the-art neurosurgery intervention relies heavily on tissue imaging information taken at a pre-operative stage. The data retrieved prior to performing an opening in the patient's skull, however, may present inconsistencies with respect to the tissue position observed by the surgeon during intervention, due to both the pulsing activity of the brain and possible displacements caused by movement...
Real-time ultrasound guidance during neurosurgery is a novel and sought-after technique that enables imaging data to be acquired with improved precision during surgical intervention. Surgical needles that are inserted in the tissue of interest can be guided using the real-time graphical information collected by an embedded ultrasound transducer. The miniaturisation capabilities of modern manufacturing...