The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
m Beitrag werden die aktuellen Anforderungen an das Detail Wand‐Decken‐Knoten im monolithischen Ziegelmauerwerk unter den Aspekten Wärmeschutz, Schallschutz, Brandschutz und Statik zusammengestellt. Schallschutz, Brandschutz und Statik erfordern möglichst große Deckenauflagertiefen. Das Gebäudeenergiegesetz (GEG) bietet die Möglichkeit zur Nutzung pauschaler Wärmebrückenzuschläge. Mit der Überarbeitung...
The paper presents results of a series of 6 in‐plane shear tests on storey‐height clay unit masonry panels [1] with thin‐layer mortar, carried out in addition to previous test campaigns [2], [3], and [4]. The walls were constructed with unfilled thermally insulating clay units with a thermal conductivity of λ = 0.09 W/(m · K).
The current design rules for clay unit masonry according to DIN EN 1996‐1‐1/NA...
The paper presents the results of a series of 6 shear tests on full scale highly thermal insulating clay unit masonry walls. The walls consisted of units with large voids filled with mineral wool with a thermal conductivity of λ = 0,07 W/(m · K).
The aim of the investigations was the verification of the in‐plane‐shear resistance of this type of thermal insulating clay unit masonry in addition to the...
In order to investigate the influence of a partially supported slab on the in‐plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with ”Arbeitsgemeinschaft Mauerziegel“. The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different...
Die Ergebnisse von 20 Schubversuchen an geschosshohen Planziegelmauerwerkswänden, die im Auftrag der Arbeitsgemeinschaft Mauerziegel durchgeführt wurden, werden vorgestellt. Die untersuchten Steinarten (gefüllte Großkammerziegel und Ziegel mit Kleinlochung) sowie die Wandgeometrien und Auflasten repräsentieren die aktuell in Deutschland verwendeten Wandaufbauten im Geschosswohnungsbau bei hohen Anforderungen...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.