The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Based on photodiode array, an optical measurement system is established for gas-liquid two-phase flow in small tubes. A method is proposed for characterization and flow regime identification of gas-liquid two-phase flow. In the experiment, different flow regimes are observed in a horizontal glass tube with inner diameter of 4.02mm and outer diameter of 6.12mm, and voltage signals are obtained from...
A simple flow regime detection method of gas-liquid two-phase flow is presented, used in mini-pipes. First, the capacitance signals are obtained, and some simple statistics eigenvalues, such as mean value, standard deviation, total energy, average amplitude, zero-crossing rate and probability density function, are analyzed and used to identify the flow regimes. The principal component analysis (PCA)...