The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper an analysis of steady-state operation in doubly-fed induction generator (DFIG) wind turbines (WT) is presented. A method based on the Newton-Raphson (NR) algorithm is proposed for obtaining the steady-state electrical variables of the machine under certain given conditions. It is of interest in the load flow analysis, when these machines are present in electrical system, but also for...