The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The effect of five parameters that affect the performance of a liquid cooling module; module orientation, charge ratio, charge temperature and air temperature have been investigated. The liquid cooling module was previously developed by the authors and comprised of an integrated assembly of a boiling plate, spacer, and condenser plate and used FC-72 as the working fluid. The size of the module was...
A liquid cooling module as a cooling means for electronic devices using boiling and condensation heat transfer was designed and its performance was investigated. The liquid cooling module was comprised of a boiling plate, spacer, and condenser plate and used FC-72 as the working fluid. The size of the module was 101 mm times 108 mm times 18 mm and the chip size (heat source) used was 10 mm times 10...