The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A PGNAA facility is being developed for 10 B concentration measurements at RA-3 reactor. Its design targets detection limits better than tenths of a microgram and irradiation times on the order of minutes. Computational models were developed, which estimated thermal neutron fluxes in irradiation position to be larger than 10 9 ncm −2 s −1 . Calculated amounts of photons...
The installation of a new Instrumentation and Control (I&C) system for the TRIGA MARK II reactor at University of Pavia has recently been completed in order to assure a safe and continuous reactor operation for the future. The intervention involved nearly the whole I&C system and required a channel-by-channel component substitution. One of the most sensitive part of the intervention concerned...