The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
As general restrictions for the design of Oxyfuel pulverised coal-fired (PC) steam generators are commonly known, the purpose of this work is to show general restrictions for the design of an Oxyfuel coal-fired steam generator using a circulating fluidised bed combustor (CFBC) with external heat exchangers (EHEs). For the CFBC restrictions result on the one hand out of the used fuels composition....
In contrast to an Oxyfuel process with pulverised coal (PC) firing, possible advantages of a circulating fluidised bed combustion (CFBC) are the in-furnace sulphur dioxide removal no additional sulphur dioxide removal downstream the steam generator might be necessary and the feasibility for concepts with a reduced flue gas recirculation. In [1] design conditions for the overall process of an Oxyfuel...