The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In an electric vehicle (EV) or hybrid electric vehicle (HEV) the control of motor drive under aberrant conditions plays a dominant role. One of it is the stator inter turn faults in the motor. It creates huge abnormality in the machine speed and torque pulsations which finally makes the operation of a drive to standstill. This paper mainly describes an algorithm to control the drive in fault-tolerant...
One of the peculiar studies on the induction machine is the aberrant behavior of the induction machine with stator inter turn faults. These are usually caused by short circuit of few turns on stator winding. In this paper transient model of three phase induction motor using d-q axis theory in stationary reference frame, is proposed to estimate the transient performance of the motor, with such faults...