The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a visual feedback available robotic gait training system for motor recovery of hemiplegic stroke survivors. The system is composed of a treadmill consisting of two split belts, a pelvic support manipulator assisting patient's pelvic movement, and a visual interface feedbacking patient's gait phase. The split-belt treadmill allow patient to walk in different velocities between sound...
With the aging population problem getting more and more aggravated, the number of hemiplegia patients increases rapidly, which results in the increasing requirement of rehabilitation training for regaining the body movement function. Taking advantages of rehabilitation robots makes the rehabilitation training more scientific and efficient compared to traditional rehabilitation measures such as manual...
Up to now, with the increasing of the elderly population, more and more patients are suffering from hemiplegia. The need for hemiplegic rehabilitation is increasing quickly. As traditional rehabilitation, each patient must be treated by therapist, one by one. However, because of the different levels of therapists, the rehabilitation cannot be performed as the as the same. Normally, the rehabilitation...
Up to now, with the increasing of the elderly population, more and more patients are suffering from hemiplegia. The need for hemiplegic rehabilitation is increasing quickly. As traditional rehabilitation, each patient must be treated by therapist, one by one. However, because of the different levels of therapists, the rehabilitation cannot be performed as the as the same. Normally, the rehabilitation...
With the developments of robotics, more and more rehabilitation robots are used to assist traditional training in rehabilitation field. In this paper, a novel ankle robot combined with 3 degrees of freedom, full fill passive-active training, subjective awareness and objective training requirements was proposed. The requirement of ankle robot was analyzed based on the ankle physical structure and real...
Nowadays, with the development of the proportion of the elderly population in the world, several problems caused by the population aging gradually into people's horizons. One of the biggest problems plagued the vast majority of the elderly is hemiplegia, which leads to the vigorous development of the physical therapists. However, these traditional methods of physical therapy mainly rely on the skill...
With the developments of robotics, it has become a fashion trend that ankle rehabilitation robots assist traditional training in rehabilitation field. In this thesis, a novel ankle robot combing with 3 degrees of freedom, combining passive-active training, subjective awareness and objective training was proposed. Prior to robot developments, the requirement of ankle robot was analyzed based on the...
Up to now, with the increasing of the elderly population, more and more patients are suffering from hemiplegia. It leads to a great need for hemiplegic rehabilitation. In traditional rehabilitation, each patient must be treated by therapist, one by one. However, since the individual differences of therapists, no effectiveness rehabilitation is guaranteed. And the rehabilitation status of patient is...
With the development of aging society, the number of hemiplegia patients grows rapidly and over 75% of survivors suffering hemiplegia need rehabilitation training. To assist therapists, series of rehabilitation training robots were carried out. However, most of current researches are only focusing on function training. They ignore the importance of neurological rehabilitation in early phrase of hemiplegia...
This paper presents a 5-DOF manipulator which consists of three parts, 1-DOF translational joint, a bendable skeleton (2-DOF for Omni-directional bending motion), and a rotatable forceps gripper (1-DOF for rotation, 1-DOF for opening/closing). The bendable segment in the manipulator achieves two orthogonal bending DOFs by pulling or pushing three parallel universal-joint-based shaft chains. Forward...
The coordination between the operator and laparoscope holder has a major effect on the process and results of laparoscopic surgery. The most intuitive method is for surgeons to manipulate the laparoscope by themselves. Here we demonstrate an endoscopic manipulator control system based on pupil movement that uses an intention recognition system to improve manipulation performance. An experimental task...
Eye-tracking technology has been applied to surgical skill improvement and can observe differences in gaze data between the experienced and novice surgeon. Some eye trackers can even detect pupil diameter. We hypothesized that differences in technical proficiency among surgeons affect the extent of changes in pupil diameter, because the higher mental workload a laparoscopic task requires, the larger...
This paper presents a robotic gait training system for neuro-motor rehabilitation of hemiplegic stroke survivors. The system is composed of a treadmill consisting of two separated belts, footprint array sensor attached below each belt for gait data acquisition, and an electroencephalography (EEG) device for monitoring brain activities during gait training. The split belt treadmill allow physical therapists...
Remote operation is commonly used in modern robotic assisted surgery. A surgeon sits beside the console to operate an input device to control the slave robotic instrument performing tissue manipulation, while guided by visual feedback. Most people have high more dexterity on one hand than in the other. Humans prefer to use their more dexterous hand to do important tasks, such as holding a needle for...
Minimally invasive surgery (MIS) is commonly used in pediatric operations. This method greatly benefits patients because of the reduced surgical trauma. To perform such surgery smoothly, doctors must be highly skilled. To reduce operating difficulties, a great deal of research on surgical systems have been carried out. However, in some cases, smaller workspaces limit the application of MIS. For example,...
Single Port Surgery (SPS) and Natural Orifice Transluminal Endoscopic Surgery (NOTES) bring the benefits: reduced surgical trauma and less patient's burden. However, they are still limited in the area of instrument dexterity and operability. This paper presents an Insertable Surgical Robot (ISR) for Single Port Access Surgery (SPAS), this robot uses multi-level architectures in the field of endoscopic...
Recently, a large amount of stroke survivors are suffering from motor impairment. However, existed therapy interventions have limited effects to restore normal motor function. Thus, we proposed a novel control strategy for gait rehabilitation of hemiplegic patients. The whole system consists of a Functional Electrical Stimulation (FES) device and Treadmill-Walk system. FES contributes to improve the...
In consideration of a large proportion of stroke survivors with persistent deficits, current interventions have limited ability to restore normal motor function. We propose a gait training system for gait rehabilitation of hemiplegic patients with convalescent stroke. It consists of a functional electrical stimulation (FES) device which is used to influence the gait pattern instantly to improve the...
This paper presents a 6-DOF manipulator which consists of four parts, 1-DOF translational joint, two 2-DOF bending joints (segment1 and segment2), and 1-DOF rotational gripper. The manipulator with “flexible shaft and Double Screw Drive (DSD) mechanism” structure can obtain omni-directional bending motion through rotation of flexible shafts. In the first prototype, the flexible shafts were connected...
In the paper, the characteristics of mode and harmonic response of the axis of the high-speed motorized spindle are presented with the FEM (Finite Element Method). A dual-dimension model with the FEM is developed and simulated using ANSYS commercial software. The result shows that the rated rotating speed of the high-speed motorized spindle is far smaller than the first-order natural resonance speed,...