The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes the use of a Fourier transfer infrared (FTIR) spectrometer, integrated with a sampling system and a control software, as a continuous emission monitor (CEM) for on-line measurement of most volatile organic and some inorganic compounds from various gas emissions. The time response of the system was tested experimentally, and can be approximated by a complete mixing model. In order...
Recent development of Fourier transform infrared spectroscopy greatly expands its potential as a continuous monitoring system for incinerator emissions. However, one of the key factors in ensuring success of this technology is obtaining a set of reliable calibration standards for the quantitation of target analytes. Experimental results in this study indicate that calibration should be conducted...