The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation...
W artykule zaprezentowano układy pomiarowe, w których istotnym elementem jest woltomierz homodynowy (Lock-In Amplifier). Układy te mogą służyć do wzorcowania mierników mocy oraz prądowych i napięciowych obciążeń przekładników. Zamieszczono też wyniki porównań z urządzeniami dedykowanymi do tego typu pomiarów.
Artykuł ten opisuje aktualnie stosowane metody wzorcowań obciążeń przekładników w wybranych krajowych instytucjach metrologicznych (GUM w Polsce, ČMI w Czechach, PTB w Niemczech).