The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The present work comprises a numerical analysis using the Ansys program to solve the problem of combined free-forced convection around a circular cylinder located in a horizontal lid-driven trapezoidal enclosure. The enclosure is filled with water. The upper moving wall and lower fixed wall are cold at a constant temperature, whereas the inclined walls are adiabatically insulated. The uniformly heated...