The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a method for monitoring of turn short-circuits faults of permanent magnet synchronous motor (PMSM) with non sinusoidal electromotive force (emf) in closed loop conditions. The proposed method is formulated by combining multi-model approach in extended Park frame and the recursive least squares algorithm (RLS). The fault and its severity are indicated by the surface of structure...
In this paper, a new technique of on-line detection of inter-turn short circuits in stator of permanent magnet synchronous motor (PMSM) is proposed. The study is focused on a PMSM with non sinusoidal electromotive force (emf). The technique is formulated by combining extended Parkpsilas vector approach and classical recursive least squares algorithm (RLS). The faults are detected by analysing the...