The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes the construction and experimental tests of a 12-kV high-voltage high-action generator based on reverse-switching dynistor (RSD) assembly. The main RSD unit consists of seven 76-mm-diameter dynistor pieces connected in series with a blocking voltage of about 2.4 kV, a magnetic switch based on a 1K101 amorphous alloy core, the trigger system based on a saturable transformer, and...
A scheme for an all-solid-state pulsed power generator is described, which incorporates an assembly of reversely switching dynistor (RSD), a magnetic compression section, a trigger circuit based on a step-up saturable pulse transformer, and a thyristor. The generator with a operating voltage 1.5 kV can switch a 2.6 kA pulse current with a full width at half maximum of about 8 μs duration, a di/dt...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.