The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Der Deutsche Ausschuss für Mauerwerk e. V. (DAfM) und die Initiative Praxisgerechte Regelwerke im Bauwesen (PRB) haben eine Forschungskooperation beschlossen. Im Rahmen eines von der PRB initiierten Forschungsvorhabens zur Bewertung der neuen Eurocode‐Generation wird sich der DAfM mit dem neuen Eurocode 6 befassen und damit den Teilbereich „Mauerwerksbau” abdecken. Konkret wurden vier Themenstellungen...
Auf Baustellen trifft man auf eine Vielzahl an Mauersteinen, die sich durch den Baustoff (Ziegel, Porenbeton, Kalksandstein, Leichtbeton oder Normalbeton), die Struktur (Vollsteine, Lochsteine mit oder ohne Dämmstoff‐Füllung), die Geometrie, die Rohdichte und die Druckfestigkeit unterscheiden.
Im Rahmen von Zulassungsverfahren für Kunststoffdübel und Metall‐Injektionsanker wird es für Dübel‐Hersteller...
In diesem Beitrag wird ein Ansatz für die Bemessung von Mauerwerk aus Porenbeton unter Brandeinwirkung vorgestellt. Dabei wird die Problematik der Berechnungsmethoden in der aktuellen Fassung der EN 1996‐1‐2 für die Bemessung von tragenden Porenbetonwänden erläutert. Die aktuelle Version der EN 1996‐1‐2 bietet nur tabellarische Daten als verlässliche Methode für die Bewertung von Tragwerken im Brandfall...
Auf Baustellen trifft man auf eine Vielzahl an Mauersteinen, die sich durch den Baustoff (Ziegel, Porenbeton, Kalksandstein, Leichtbeton oder Normalbeton), die Struktur (Vollsteine, Lochsteine mit oder ohne Dämmstoff‐Füllung), die Geometrie, die Rohdichte und die Druckfestigkeit unterscheiden.
Im Rahmen von Zulassungsverfahren für Kunststoffdübel und Metall‐Injektionsanker wird es für Dübel‐Hersteller...
Zyklische Schubversuche sind eine gängige Methode, um die Tragfähigkeit und das Verformungsverhalten von Wänden bei dynamischen Belastungen in horizontaler Richtung, wie sie zum Beispiel bei Erdbeben auftreten, zu beurteilen. In der vorliegenden Arbeit werden zyklische Schubversuche an 36 Wänden aus verschiedenen Mauerwerksarten beschrieben, die Testergebnisse gezeigt und mit rechnerischen Widerständen...
Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks‐ und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden...
Im Tagesgeschäft der Tragwerksplanung sind praxisnahe Bemessungshilfen eine wichtige Unterstützung. Die Bemessung primär vertikal beanspruchter Mauerwerkswände im üblichen Hochbau kann mittels sogenannter Tragfähigkeitstafeln erfolgen. Dabei wird ausschließlich in Abhängigkeit der geometrischen Gegebenheiten ein Tafelwert abgelesen, welcher – multipliziert mit der Mauerwerksdruckfestigkeit – die Normalkrafttragfähigkeit...
Brüstungsmauerwerk wird in der Bemessung häufig vernachlässigt. Muss ein Nachweis jedoch explizit geführt werden, so ist dies häufig nur unter Ansatz der Biegezugfestigkeit wirtschaftlich möglich. Für diesen Anwendungsfall werden zwei Bemessungsverfahren vorgestellt, mit denen Brüstungsmauerwerk als freistehende Wand unter Ansatz der Biegezugfestigkeit nachgewiesen werden kann. Neben einem allgemeinen...
According to Eurocode 6, unreinforced masonry walls can be designed using different verification methods, whereby the simplified calculation methods are contained in Part 3 of DIN EN 1996 [1]. If the associated application limits and boundary conditions are fulfilled, a large part of the usual problems occurring in masonry construction can be dealt with without great effort. A limiting condition for...
According to the German National Annex to DIN EN 1996‐3, a calculative verification of the bracing system may be omitted if, besides other requirements, an obviously sufficient number of sufficiently long shear walls is in place. If it is questionable whether a building complies with this requirement, a time‐consuming verification of the bracing system according to DIN EN 1996‐1‐1/NA is unavoidable...
Partial safety factors for resistance applied in the design equation of semi‐probabilistic formats can be obtained from the evaluation of a test database. These partial safety factors are influenced by two factors, the material uncertainty and the model uncertainty. This topic is covered in a former publication [1]. It includes the determination of a partial factor for the model uncertainty of unreinforced...
The study outlined in this article was intended to quantify the lifecycle assessment effects resulting from the different thermal storage capacities of the market‐relevant construction methods masonry, reinforced concrete and timber frame. Independently reviewed and verified life cycle assessments of representative model homes were the starting point of this study. But the findings of available computer...
In order to investigate the influence of a partially supported slab on the in‐plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with ”Arbeitsgemeinschaft Mauerziegel“. The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different...
Until now, the standards framework for the energy‐related balancing of buildings has concentrated on the operating/use phase of the building by using energy consumption or demand values as the essential parameters. Energy used for the production of the building materials, the building of the building and finally any disposal required are not included. The German government therefore formulated the...
The semi‐probabilistic safety concept of divided safety factors for action and resistance of DIN EN 1990 [1] in combination with the structural design codes DIN EN 1996‐1‐1 [2] and DIN EN 1996‐1‐1/NA [3] include the requirement that acting normal forces NEd may not exceed the normal force resistances NRd for the structural design of masonry under bending compression. According to [3], fully plastic...
The design/verification method in the Eurocodes is based on the partial safety concept. Eurocode 6 suggests a constant partial safety factor for the material γM for all design/verification problems, without consideration of model uncertainty in the design/verification formula. In the following, a model partial safety factor is determined for the problem of unreinforced masonry walls mainly subjected...
Das semiprobabilistische Sicherheitskonzept geteilter Sicherheitsbeiwerte für Einwirkungs‐ und Widerstandsgrößen von DIN EN 1990 [1] führte in Deutschland zum Vergleich widerstehender Biegemomente und Normalkräfte mit den entsprechenden einwirkenden Schnittgrößen bei der Bemessung von Mauerwerksbauteilen.
Hinsichtlich der Werkstoffeigenschaften für Mauerwerk unter Biegedruckbeanspruchung wird in DIN...
The article presents the investigation of the seismic behaviour of a modern URM building located in the municipality of Finale Emilia in province of Modena, Northern Italy. The building is situated in the centre of the series of the 2012 Northern Italy earthquakes and has not suffered any damage during the earthquake series in 2012. The observed earthquake resistance of the building is compared with...
In the course of the revision of EN 1996‐1‐1, a new proposal has been made for the calculation of internal forces in frame‐type structures for the determination of bending moments due to slab rotation. In addition to a stiffness reduction for masonry walls in conjunction with the special features of partially supported slabs, which is already usual in Germany, the calculated ever‐present minimum loadbearing...
This paper deals with the design of basement walls subjected to lateral earth pressure. The current simplified calculation method according to DIN EN 1996‐3/NA only covers active earth pressure, which is the lower limiting value of the earth pressure. Designing according to DIN EN 1996‐1‐1/NA, higher coefficients of earth pressure (like earth pressure at rest) can be considered, with an additional...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.