The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
With the increasing development of wind power, the capacity of wind farms is larger and its impact on grid operation has become more prominent. The fault current that wind farms provide is much different from the traditional synchronous machines. Wind farms in China are mostly centrally connected to power system. The central integration enlarges the impacts on power system. The correct action of the...
This paper investigates the settings of the generator out of step protection relays (ANSI device 78) for all six gas and steam turbine generators used in a grid connected CHP power plant. Detailed model of the CHP power system is developed in PSCAD/EMTDC tool which includes a representation of the synchronous generator, turbine governor, Automatic Voltage Regulator (AVR), Power System Stabilizer (PSS),...
To solve the problem of the control of conventional grid-connected with hard switch, the instant large surge current of connected-grid, the long time interval of grid-connected, the islanding effect of grid -connected and the PVGS (photovoltaic generation system) not being broken away from grid quickly, the flexible control strategy was proposed to realize connected-grid with bidirectional SCR. This...
Selection of the DG interconnection protective relay is based on several criteria such as power system characteristics, the dynamic response of the generator, the system grounding, the DG transformer connection, etc., as well as the protection policy of the utility and coordination requirements. The interconnection protection IED design can be summarized as follows: Disconnection of DG plants when...
Wind speed varies continuously throughout a day resulting in fluctuating wind farm output power. When such a farm is connected to the grid through a line, the transmitted power and the relay end voltage (with respect to grid voltage) fluctuate continuously. In this paper, the protection of such a line with distance relay is investigated. The ideal trip characteristic for distance relay is studied...