The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Linear, nonlinear and test comparison analyses of flat plate slabs with shear reinforcement are presented in the article. Analyses of slabs with and without shear reinforcement by nonlinear simulations are introduced. The calculations of slabs without and with 0.16 m eccentricities were performed. For analyses finite element method were used. Design models of flat slab with column by “Lira SAPR” software...
The four storey in situ reinforced concrete frame-wall building by flat plate system is presented in the article, which under static and seismic loads was calculated. Only the middle column of the building in the paper was reviewed and all computations by LIRA were done. The calculations according to Armenian and Russian building codes were implemented and satisfied these conditions. The supremum...