The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Two different methods to determine the effective thermal conductivity of six Mexican cementing systems used in geothermal well completion were compared in the temperature range from 28 to 200 o C. Measurements were taken using the classical line-source method and the Jaeger method. The experimental thermal conductivity uncertainties were 4% and 11.8% for the line source and Jaeger's methods,...