The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Dc-capacitor voltage drift phenomenon is the main technical issue of an n-level (n>;3) Diode-Clamped Converter (DCC). This paper presents a predictive current control strategy for a three-phase five-level DCC which enables simultaneous control of ac-side currents and balance of capacitor voltages. The paper derives a discrete-time dynamic model of a five-level DCC. Based on the derived model, a...
High Voltage Direct Current (HVDC) transmission systems are now getting more popular due to their low power losses and fast controllability of power in DC lines as compared to AC systems currently used. The primary goal for this study is to control the voltage and power flow direction by adjusting the firing angles of rectifier (α) and extinction angle of inverter (γ). Constant Extinction Angle (CEA)...
This paper deals with an integrated solid state controller (ISSC) for an isolated asynchronous generator (IAG) used in small hydro power generation for feeding three-phase four-wire loads. The proposed ISSC is used to control the voltage and frequency of IAG. This ISSC is realized using a three-leg insulated gate bipolar transistors (IGBTs) based current controlled voltage source converter (CC-VSC),...
This paper deals with a decoupled electronic load controller (DELC) for an isolated asynchronous generator (IAG), used in constant power pico hydro power generation for feeding three-phase four-wire loads. The proposed DELC is used to control the voltage and frequency in the decoupled manner. The proposed decoupled electronic load controller is combination of a voltage regulator (VR) for regulating...
A tension adaptive variable-structure control system was designed for constant tension of electric cable plastic wrapping automatic production process. This system contains two inner loops for current and velocity control using PI regulators; its outer loop is for tension control using model reference adaptive controller. Simulation results indicate that the adaptive variable-structure controller...
In this paper, the linear mathematical model of three phase Voltage Source Rectifier (VSR) in d-q coordinates is deduced based on the power balance equation and decoupled state-feedback control method. An improved control strategy using current inner loop with state feedback decoupling, voltage square outer loop and SVPWM modulation is proposed. Nonlinear input transformation is used to derive a linear...
This paper presents a Matlab/simulink model of grid-connected photovoltaic (PV) system, including a PV array, a control system, a distribution network and a load. Based on the accurate modeling system, optimum control and stability analysis are studied. The current control strategy can regulate the current at the point of common coupling to achieve the power factor control. The voltage control strategy...
The circuit and corresponding steady state vectors' relationship of single-phase PWM rectifier using IGBTs (insulated gate bipolar transistors) is analyzed, and the mathematic model and controller structure are presented, the PI regulators of the current and voltage loops are designed respectively. The method based on the Matlab/Simulink Blocks is used to carry out the simulation for the control system...
A new complete RBF neural network SVPWM controller scheme for a grid-connected inverter is presented in this paper, RBF network architecture and the parameter is determined by using the clustering method, the RBF neural network which is simplifies and realize voltage space vector modulate to control the inverter. It was used in three-phase photovoltaic grid-connected inverse system which adopts control...
This paper presents a review of some techniques for islanding detection, especially by using inverter based DG applications and it also focuses on several islanding detection methods for a single-phase current-control voltage inverter working with a PV system connected into the grid. It is deliberated a single-phase inverter with maximum power of 5 kW. Islanding detection methods are investigated,...
In this paper, a new control strategy based on current mode control for dynamic voltage restorer (DVR) is proposed to mitigate the power quality problems in the supply voltage. The DVR is controlled indirectly by controlling the supply current. The reference supply currents are estimated using the sensed load terminal voltages and the dc bus voltage of DVR. The control scheme is based on synchronous...
This paper deals with the decoupled voltage and frequency controller (DVFC) for isolated asynchronous generator (IAG) used in pico hydro power generation for feeding 3-phase, 4-wire loads. The proposed controller is used to control the voltage and frequency through control of active power at the generator terminal independently. The decoupled controller is a combination of a static compensator (STATCOM)...
This paper deals with different control strategies for DSTATCOM (distribution static compensator) for power quality improvement for a three-phase, three-wire distribution system. A three-leg voltage source inverter (VSI) configuration with a dc bus capacitor is employed as DSTATCOM. The hysteresis as well as PWM current controllers are designed, analyzed and compared for PI controller and sliding...
Interest of renewable energy sources increases with the increasing world power demand and decreasing of fossil energy sources. Many of the new energy sources like the PV, the fuel cell or the wind, produces direct voltage so it is needed a suitable direct current to alternating current inverter to connect them to an alternating current load or the utility line. In this case utility interactive inverters...
This paper deals with the voltage and frequency controller (VFC) for isolated asynchronous generator feeding 3-phase 4-wire loads for constant power applications such as pico hydro uncontrolled turbines. An AC capacitor bank is used to self excite and to meet the reactive power requirement of the asynchronous generator which is also known as self excited induction generator (SEIG). The proposed VFC...