The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper discusses the active and reactive power control method for a modular multilevel converter (MMC) based grid-connected PV system. The voltage vector space analysis is performed by using average value models for the feasibility analysis of reactive power compensation (RPC). The proposed double-loop control strategy enables the PV system to handle unidirectional active power flow and bidirectional...
This paper presents a unified selective harmonic compensation strategy using DG-interfacing inverter with LCL filter in the presence of nonlinear local loads for both grid-connected and islanded microgrid. Compared with the existing harmonic compensation methods in the literature, the proposed strategy consists of a triple-control-loop in the grid-connected mode to compensate the grid current harmonics...
High frequency is an effective method to improve transmission efficiency of inductively coupled power transfer (ICPT) system. However, it is hard for the high capacity semiconductor device to meet the high frequency need. In this paper, a novel multiple-frequency inductively power transfer system is proposed. By adopting a novel multiple-frequency topology of inverter, the transfer frequency of the...
This paper presents a concept for a compact high voltage generator based on a highly integrated power chain switching at frequencies above 500 kHz. The high frequency operation in combination with the high integration approach enable a reduction of volume and weight of HY-generators used in industrial or medical applications.
The problems associated with the harmonics needs more attention as more number of distributed generators like PV and wind are integrated into a distribution system. Although the integration presents a lot of benefits, satisfying the needs of local load requirements by reducing the line losses and facilitating congestion management, the problems of power quality that impact the distribution system...
In this paper, a sensorless active damping scheme of LCL-filter is proposed in grid-connected parallel inverters for battery energy storage systems. The proposed damping method is superior to the conventional notch filter and virtual damping methods with respect of robustness on the variation of resonance of the filter and unnecessary additional current sensors. The theoretical analysis of the proposed...
This paper introduces a new Wireless Power Transfer (WPT) system based on single pair of electric field coupling without a current return path. Such a single-contact Capacitive Power Transfer (CPT) system helps to enhance the coupling tolerance between the coupled plates. A class E converter is designed to drive an LCLC resonant circuit to boost the voltage at the primary side of the coupling plate,...
A typical distributed generation application (DG) only operates in grid-connected mode, for safety reasons. Recently, changes in Brazilian legal framework authorized islanded operation in some cases. This paper presents a dual mode LCL VSI for DG applications. The proposed system can operate in both, grid-connected or islanded, commutating between modes seamlessly. It was designed to operate with...
A segment control scheme of inductive power transfer (IPT) system for rail transit is proposed in this paper. In this scheme, the power supply range of primary coils along the track is segmented into several intervals and the several sets of pickups are installed aboard. When the vehicle runs, the switching frequency and the reference current of inverters is modulated with the position of the pickup...
This paper is focused on the possibilities of implementing an auto-adaptive control, without a phase-locked loop circuit, for the operating frequency in an induction heating system with single-phase voltage source inverter and resonant L-LC load. Based on the phasor diagram of the equivalent resonant load under resonance condition, three possibilities have been identified to express an error to be...
This paper presents the design and implementation of a power supply unit for zone-less induction cook-top. Here a control algorithm is also presented for tracking the user activity which includes misalignment of pan above the coil and removal of pan. The control algorithm is implemented using a DSP processor. The power supply consists of a power stage, control stage, and digital control algorithm...
In this paper, the design of a proportional resonant (PR) controller for the packed U cell (PUC) 5 level inverter is presented. The objective of the presented work is to present a better solution for current control in grid connected application of the investigated topology. A suitable LCL filter is designed along with the PR control scheme for grid connection. Simulation is performed in MATLAB®/Simulink...
In recent years, as an eco-friendly EV charging system, the wireless charging has become a topic due to the merits such as convenient, safety, and clean. In this paper, in order to realize a large-gap wireless charger which can communicate between the power feeding and receiving units without any additional communication device, a wireless power transfer (WPT) system using a single-ended push-pull...
Induction heating (IH) appliances are widely used for industrial appliances and home electronics because IH has a lot of merits. Recently, wireless power transfer attracts attention as a promising industry. As for wireless power transfer, inductance is changed in accordance with power transmission distance or surrounding environment. Similarly as for IH, inductance and resistance as equivalent circuit...
This paper investigates the mutual interaction and stability issue of multi-parallel LCL-filtered inverters. The stability and power quality of multiple grid-tied inverters are gaining more and more research attention as the penetration of renewables increases. In this paper, interactions and coupling effects among the multi-paralleled inverters and power grid are explicitly revealed. An Interaction...
Magnetically-coupled resonant wireless power transfer (MCR-WPT) offers a novel technique to transfer power over a long distance with high efficiency. A half bridge inverter with series-resonant structure is designed as driver source for WPT system in this paper. The frequency is up to 0.9MHz, which is very higher than traditional power electronic converter. The relationship between output power, transmission...
This paper presents the control method of an LCL filter implemented for a three-phase, voltage-source, grid-connected inverter for not only offering better attenuation of switching harmonics but also for highly damping the resonance. A discrete-time deadbeat current controller with tuned state-feedback gains is proposed to realize the time optimum responses with high control accuracy. In addition,...
An alternative implementation of asymmetric cascaded H-bridge (ACHB) inverter is presented in this work. The presented ACHB inverter is using a single DC source. The main bridge is directly connected to the DC source (such as, battery, fuel cell or photovoltaic array). And the auxiliary bridges are fed by isolated series resonant converter (SRC). Voltage of the auxiliary bridge is balanced by controlling...
This paper discusses the emulation of an active RLC load by means of an inverter. To this purpose, a suitable current control strategy is analyzed and developed. The limitations of this approach are explored, highlighting the requirements of the adopted regulator in order to avoid instability issues. The proposed analysis and model of the controlled system are verified by means of simulations and...
A design for the inverter circuit configuration of integrated half-bridge modules with a focus on the circulating resonant current is clarified in this paper. Although this configuration has the advantages of small DC-side stray inductance, an analysis of the equivalent circuit suggests that a DC-side capacitor current increases depending on the relationship between the resonant and switching frequencies...