The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Thermal tests of the combined cycle (steam-gas) unit at the CHPP No. 26 Mosenergo have been carried out, with measurements of the power and efficiency of the steam-gas unit, as well as the flow rates and parameters of the heat transfer media (air, combustion products, water, and steam) over a wide range of electrical loads and ambient air temperatures. The maximum electric power of the combined cycle...