The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents the Direct model reference adaptive internal model controller for doubly fed induction generator used in wind farms based on MIT Rule adjustment mechanism with dither injection. Direct model reference adaptive internal model controller is developed and it is tuned using MIT rule. Rotor current controller is designed using direct model reference adaptive internal model controller...
With real time digital simulator (RTDS), new control strategy for low voltage ride through (LVRT) is developed for a doubly fed wind power induction generator (DFIG). Specifically, adaptive control method is proposed to limit high peak rotor current. Furthermore, current limiters are connected in three-phase rotor circuits, which are strategically controlled by thyristor switches to counter the effect...
This paper presents the direct model reference adaptive internal model controller for doubly fed induction generator used in wind farms based on MIT rule adjustment mechanism in addition to Perrin equation adjustment mechanisms with improved internal model controller filter design. Direct model reference adaptive internal model controller is developed and it is tuned using MIT rule adjustment mechanism...
Wind power generation system is typical multi-variable, non-linear and too complex to build precise mathematical model. In order to capture maximum energy at certain wind speed range and regulate active and reactive power independently, adaptive fuzzy control based on stator flux-oriented vector control was adopted. The simulation program was written in C compile language and Matlab. The results show...