The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A new flexible, dry electrode is examined for recording surface electromyographic signals and compared to a conventional Ag/AgCl electrode. A suitable dry electrode would enable practical implementation of wearable mobility monitoring systems. Results from a preliminary experiment are presented in this paper. Measurements were performed on the right tibialis anterior during a series of small and large...
This paper presents the development of a network platform which allows connecting multiple individual wireless devices for transmitting bioelectrics and biomechanics signals for application in a hospital network, or continuous monitoring in a patient's diary life. The Zigbee platform development proposal was made in three stages: 1) Hardware development, including the construction of a prototype network...
An exercise test delivers a large number of measurements that are valuable in risk prediction, in detecting coronary artery disease, and in describing the functional exercise response of a patient. However, it is difficult to have comprehensive knowledge of all measurements and their thresholds. The Exercise Test Interpretation (XTI) program compares exercise measurements against established thresholds...
In this study, we have used impedance cardiography to determine blood pressure (BP) cufflessly and non-invasively. We have devised a new parameter, QdZ [the duration measured from the foot of electrocardiogram (ECG) Q wave to the peak of impedance cardiogram (ICG)], for this purpose. Twenty-two subjects performed four minutes of treadmill exercise such that systolic BP (SBP) was increased significantly...
Arterial stiffness is an important index for cardiovascular events. The objective of this study is to examine possible parameters related to arterial stiffness that can be estimated during simple arm movements. An experiment was conducted on 32 subjects divided into two groups, one with an age of 26plusmn4 years old, and the other 61plusmn9. The pulse transit time measured from electrocardiogram to...
Pulse transit time (PTT) has been widely used for noninvasive examination of the arterial viscoelastic properties, such as elasticity, compliance, and stiffness of the vessel walls. PTT is usually determined as the time interval between the peak of the electrocardiogram R wave and the foot of the photoplethysmogram (PPG). However, it was observed that the PPG is affected by the applied contact force...
We develop a computational framework for estimating simultaneously mechanical properties (active stress, passive elasticities, and mechanical activation time) and electrical properties (current density and electrical activation time.) First, we present a method for estimating the mechanical properties, active stress and passive elasticity modulus, of the in vivo heart using magnetic resonance imaging...