The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Generator rotor and stator vibration characteristics on stator winding inter-turn short circuit fault are analyzed. Through calculating the generator parameters of air-gap magnetomotive force, air-gap magnetic field energy and magnetic flux density on the fault, the frequency characteristic of imbalance magnetic pull acting on rotor and that of pulsating magnetic pull acting on stator core are found...