The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Quasi uniform field gaps, namely sphere gaps are quite often used in high voltage laboratories. In the present work, both simulation and experimental results to see the electric stress distribution on breakdown voltage are presented. Considering commonly used vertical arrangement of sphere gaps, disruptive discharge voltages are measured experimentally. These experiments are with one sphere grounded...
Quasi uniform field gaps, namely sphere gaps are quite often used in high voltage laboratories. They exhibit very little polarity effect when subjected to direct high voltages. But if their electric field is disturbed by a near by earthed object they tend to show polarity effect. In the present work, both simulation and experimental results to see the electric stress distribution on breakdown voltage...