The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes the causes of cogging torque in Permanent Magnet synchronous Motor. Establishes a motor model by ANSOFT software, uses Finite Element Method to quantitative analysis and comparative peak cogging torque and torque with notches at different locations, and different number of auxiliary slot. The conclusion is that notch reasonable can reduce the cogging torque of permanent magnet...