The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a new approach in adaptive out-of-step (OOS) protection settings in power systems in real time. The proposed method uses extended equal area criterion (EEAC) to determine the critical clearing time and critical clearing angle of the system, which are vital information for the OOS protection setting calculation. The dynamic model parameters and the coherency groups of the system...
Wind power installed capacity is expected to reach 1,000 MW and 6,200 MW in the Vietnam Power System (VPS) in 2020 and 2030, respectively. But detailed dynamic analysis of the wind power plants' (WPPs) integration into the VPS is still scarce. In this paper, first, the impact of WPPs' integration on the dynamic voltage performance and the wind turbine generator (WTG) low-voltage-ride-through (LVRT)...
Autoreclosure provides a means of improving power transmitting ability and system stability. The conventional reclosure adopts the fixed dead time interval strategy, that is, the reclosure is activated after a time delay to restore the system to normal as quickly as possible without regard to the system conditions; however, these simple techniques cannot give the optimal operating performance. For...
Distributed generators (DGs) that are rated between several kVA and 250 kVA in size are increasingly being connected at the 400 V electrical distribution level. Therefore, new requirements for the traditional network protection schemes and the co-ordination between network protection and intertie protection are needed. Actual problems have been experienced relating to DG transient behaviour, thereby,...
This paper reviews the behavior of electrical systems when they are subjected to oscillations which can cause that one or more synchronous machines loose synchronism with each other. The paper makes a detailed reference to power swing blocking and out of step relays whose operation has to assure adequate protection under these conditions. A thorough procedure is discussed to set out of step relays...