The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A fixture was designed and built to test power cycling reliability at maximum junction temperatures of 150°C and 175°C. A 1200V, 150A IGBT six pack module was mounted on a single cold plate and three sets of cold plates were connected to DC power supplies controlled by LabView. The IGBTs on each cold plate were cycled to give a junction-to-case temperature rise of 100°C with a maximum junction temperature...
In order to meet the through-life reliability targets for power modules, it is critical to understand the response of typical wear-out mechanisms, for example wire-bond lifting and solder degradation, to in-service environmental and load-induced thermal cycling. Application of accurate wear-out models can identify the dominant failure mechanisms at the design stage and can be employed in reliability...